Difference between revisions of "Dell Powerconnect 5324"
(→via console xmodem in linux) |
(→CLI) |
||
Line 27: | Line 27: | ||
*http://www.dell.com/support/troubleshooting/us/en/555/Index | *http://www.dell.com/support/troubleshooting/us/en/555/Index | ||
*http://en.community.dell.com/support-forums/network-switches/f/866/t/17879897.aspx | *http://en.community.dell.com/support-forums/network-switches/f/866/t/17879897.aspx | ||
+ | |||
+ | ==Set Device IP Address== | ||
+ | |||
+ | enable | ||
+ | configure | ||
+ | username admin password dell level 15 | ||
+ | interface VLAN 1 | ||
+ | ip address 192.168.1.123 /24 | ||
+ | exit | ||
+ | ip default-gateway 192.168.1.1 | ||
+ | snmp-server community private rw | ||
+ | exit | ||
+ | |||
+ | Test then save your config. You should be able to login (http,telnet) to the device. | ||
=Reset/Blank Password= | =Reset/Blank Password= |
Revision as of 10:19, 21 July 2012
To work with this switch you are going to need a NULL modem serial adapter or NULL modem cable. Once you have that The terminal settings are 9600 8N1 with no flow control. So 9600 baud, 8 data bits, 1 stop bit, and no parity. Flow Control NONE. VT100 Emulation.
Contents
Notes From Reading User Guide of Switch
- RS-232 Console Port
One DB-9 connector for a serial terminal connection which is used for debugging, software download, etc. The default baud rate is 9600 bps. The baud rate can be configured from 2400 bps up to 38400 bps.
The SFP ports and ethernet ports 21-24 can not be used at the same time.
- The device has the following physical dimensions:
- Height — 44 mm (1.73 inch)
- Width — 440 mm (17.32 inch)
- Depth — 255 mm (10.03 inch)
Speed/link/activity is indicated on the left LED and the duplex mode is indicated on the right LED.
Diag lights 4 in a row.
The reset button, located on the front panel, manually resets the device.
CLI
When using cli to save settings:
console# copy running-config startup-config
- http://www.dell.com/support/troubleshooting/us/en/555/Index
- http://en.community.dell.com/support-forums/network-switches/f/866/t/17879897.aspx
Set Device IP Address
enable configure username admin password dell level 15 interface VLAN 1 ip address 192.168.1.123 /24 exit ip default-gateway 192.168.1.1 snmp-server community private rw exit
Test then save your config. You should be able to login (http,telnet) to the device.
Reset/Blank Password
It looks like a temp operation unless you save the settings. You have to console into the switch. Reset it. On startup of the switch you will be prompted to hit esc or enter:
Autoboot in 2 seconds - press RETURN or Esc. to abort and enter prom.
Afer you hit enter or esc you get 6 options. 3 clears the password. I bet you the password comes back on reset.
Reset Configuration
Console into the switch. Reset it. On startup of the switch you will be prompted to hit esc or enter:
Autoboot in 2 seconds - press RETURN or Esc. to abort and enter prom.
press [2] within two seconds to erase flash file. Do Yes. The filename you want is:
config
Enter to continue and boot the device. Make sure to have the firmware file downloaded before you reset the switch that has your working internet connection on it.
Upgrading Switch Software
Software has a .ros extension Boot code has a .rfb extension
It looks like you do the software first and then the boot code. But you must do them both or your device will reboot over and over!
via console xmodem in linux
- Console In
enable reload
- Y to reboot the swtich
- Return or Esc within two seconds
- 1 to download software
Send file via xmodem. I use minicom. Along with minicom you need to have lrzsz installed. Some say to use screen with minicom because the transfer will take a while over serial. If you use screen and minicom you will need to change the escape key of one of them. Usually minicom under screen and keyboard (minicom -o)