− | + | [[http://files.hackspherelabs.com/?download=5324UG.zip Dell Powerconnect 5324 Userguide]] | |
+ | [[http://files.hackspherelabs.com/?download=5324CLI1.zip Dell Powerconnect 5324 Command Line Interface Guide]] | ||
+ | |||
+ | This guy has a decent setup guide: http://stevejenkins.com/blog/2011/05/dell-powerconnect-5324-setup-tasks/ | ||
+ | |||
+ | As far as passwords go it looks like the username/password thing by default is only for the web interface. When I set a line password for ssh I could use any username to login and it just asks for password. | ||
=Notes From Reading User Guide of Switch= | =Notes From Reading User Guide of Switch= | ||
− | * | + | *Page numbers and reference |
− | + | *Passwords: 56 | |
+ | |||
The SFP ports and ethernet ports 21-24 can not be used at the same time. | The SFP ports and ethernet ports 21-24 can not be used at the same time. | ||
Line 18: | Line 24: | ||
The reset button, located on the front panel, manually resets the device. | The reset button, located on the front panel, manually resets the device. | ||
+ | |||
+ | =minicom - Archlinux Install and minicom general use - Serialing in AKA Console Into Switch= | ||
+ | To work with this switch you are going to need a NULL modem serial adapter or NULL modem cable to connect to the RS-232 Console Port. Once you have that The terminal settings are 9600 8N1 with no flow control. So 9600 baud, 8 data bits, 1 stop bit, and no parity. Flow Control NONE. VT100 Emulation. | ||
+ | pacman -Sv minicom lrzsz | ||
+ | General Use: [[minicom]] | ||
+ | Settings for Dell 5324 Switch: | ||
+ | 9600, 8, N, 1, Hardware flow control OFF | ||
+ | I had to set hardware flow control off to get the unit to accept input <ref>https://stackoverflow.com/questions/3913246/cannot-send-character-with-minicom</ref>. Software flow control worked. I also had to start with 9600, I think you can change the setting later. | ||
+ | |||
+ | One DB-9 connector for a serial terminal connection which is used for debugging, software download, etc. The default baud rate is 9600 bps. The baud rate can be configured from 2400 bps up to 38400 bps. | ||
+ | |||
+ | =Reset Switch to Default Settings= | ||
+ | enable | ||
+ | delete startup-config | ||
+ | reload | ||
+ | *https://www.dell.com/community/Networking/Dell-PowerConnect-5324-How-do-you-reset-to-factory-defaults/m-p/2069264 | ||
=CLI= | =CLI= | ||
Line 28: | Line 50: | ||
*http://en.community.dell.com/support-forums/network-switches/f/866/t/17879897.aspx | *http://en.community.dell.com/support-forums/network-switches/f/866/t/17879897.aspx | ||
− | =Reset/Blank Password= | + | ==Set Console Password== |
+ | enable | ||
+ | config | ||
+ | aaa authentication login default line | ||
+ | aaa authentication enable default line | ||
+ | line console | ||
+ | login authentication default | ||
+ | enable authentication default | ||
+ | password yOurElitePassw0rd | ||
+ | end | ||
+ | |||
+ | 20 chars long seems to work and save your config: | ||
+ | |||
+ | copy running-config startup-config | ||
+ | |||
+ | ==Set Other Passwords== | ||
+ | |||
+ | You can set other passwords for other lines (ways to connect) I think they are just enable passwords and such. You would still need users and passwords (prolly @ level 15) to use these services. The services are not automatically enabled. (I think except http) | ||
+ | |||
+ | Look at the user guide starting on page 56 | ||
+ | |||
+ | [http://files.hackspherelabs.com/?download=5324UG.zip 5324 Userguide] | ||
+ | |||
+ | ==Set Device IP Address== | ||
+ | |||
+ | enable | ||
+ | configure | ||
+ | username admin password dell level 15 | ||
+ | interface VLAN 1 | ||
+ | ip address 192.168.1.123 /24 | ||
+ | exit | ||
+ | ip default-gateway 192.168.1.1 | ||
+ | snmp-server community private rw | ||
+ | exit | ||
+ | |||
+ | Test then save your config. You should be able to login (http,telnet) to the device. | ||
+ | |||
+ | ==Reset/Blank Password== | ||
It looks like a temp operation unless you save the settings. You have to console into the switch. Reset it. On startup of the switch you will be prompted to hit esc or enter: | It looks like a temp operation unless you save the settings. You have to console into the switch. Reset it. On startup of the switch you will be prompted to hit esc or enter: | ||
Line 34: | Line 93: | ||
Afer you hit enter or esc you get 6 options. 3 clears the password. I bet you the password comes back on reset. | Afer you hit enter or esc you get 6 options. 3 clears the password. I bet you the password comes back on reset. | ||
+ | |||
+ | ==Enable SSH Server Management! Plus HTTPS?== | ||
+ | I think you should still need to set a ssh line password. Though you may not have to. It looks like you do. | ||
+ | |||
+ | enable | ||
+ | config | ||
+ | crypto certificate 1 generate key-generate | ||
+ | crypto key generate dsa | ||
+ | crypto key generate rsa | ||
+ | ip ssh server | ||
+ | If you want to change ssh port: | ||
+ | ip ssh port [port #] | ||
+ | If you want http server: | ||
+ | ip https server | ||
+ | If you want public key authentication for ssh: | ||
+ | ip ssh pubkey-auth | ||
+ | If you want to turn public key off after enableing? | ||
+ | no op ssh pubkey-auth | ||
+ | exit | ||
+ | |||
+ | ==VLANS== | ||
+ | Connect two trunk ports up that have the same vlans and the switches will pass data inbetween vlans. You can do the same with a LAG or what not too. | ||
+ | |||
+ | * http://en.community.dell.com/support-forums/network-switches/f/866/t/19335968.aspx | ||
+ | *Use web interface | ||
+ | *Page 254 of the UG though | ||
+ | *Page 40 and more in the CLI Guide | ||
+ | |||
+ | Table 7-65. | ||
+ | VLAN Port Membership Table | ||
+ | Port Control Definition | ||
+ | |||
+ | T The interface is a member of a VLAN. All | ||
+ | packets forwarded by the interface are tagged. | ||
+ | The packets contain VLAN information. | ||
+ | |||
+ | U The interface is a VLAN member. Packets | ||
+ | forwarded by the interface are untagged. | ||
+ | |||
+ | F The interface is denied membership to a VLAN. | ||
+ | Blank The interface is not a VLAN member. Packets | ||
+ | associated with the interface are not forwarded. | ||
+ | |||
+ | ===Trunk VS General=== | ||
+ | *http://en.community.dell.com/support-forums/network-switches/f/866/t/19335968.aspx | ||
+ | |||
+ | ===Notes=== | ||
+ | *http://en.community.dell.com/support-forums/network-switches/f/866/p/17774016/17897002.aspx#17897002 | ||
+ | *http://stevejenkins.com/blog/2011/05/dell-powerconnect-5324-setup-tasks/ | ||
=Reset Configuration= | =Reset Configuration= | ||
Line 49: | Line 157: | ||
=Upgrading Switch Software= | =Upgrading Switch Software= | ||
− | Software has a .ros extension | + | show version |
− | Boot code has a .rfb extension | + | |
+ | *Software has a .ros extension | ||
+ | *Boot code has a .rfb extension | ||
It looks like you do the software first and then the boot code. | It looks like you do the software first and then the boot code. | ||
Line 56: | Line 166: | ||
{{Note| New firmware and new boot code must upgraded at the same time.}} | {{Note| New firmware and new boot code must upgraded at the same time.}} | ||
==via console xmodem in linux== | ==via console xmodem in linux== | ||
− | {{Note | Instructions say that this could take an hour or longer. I may just setup a TFTP server.}} | + | {{Note | Instructions say that this could take an hour or longer. I may just setup a TFTP server. You should review the image guide and user manual for the product.}} |
+ | *For the above note: https://wiki.archlinux.org/index.php/Tftpd_server | ||
+ | How: | ||
* Console In | * Console In | ||
enable | enable | ||
Line 67: | Line 179: | ||
Send file via xmodem. I use minicom. Along with minicom you need to have lrzsz installed. Some say to use screen with minicom because the transfer will take a while over serial. If you use screen and minicom you will need to change the escape key of one of them. Usually minicom under screen and keyboard (minicom -o) | Send file via xmodem. I use minicom. Along with minicom you need to have lrzsz installed. Some say to use screen with minicom because the transfer will take a while over serial. If you use screen and minicom you will need to change the escape key of one of them. Usually minicom under screen and keyboard (minicom -o) | ||
+ | |||
+ | ==Via TFTP== | ||
+ | Do it this way. | ||
+ | * Setup a TFTP server https://wiki.archlinux.org/index.php/Tftpd_server | ||
+ | enable | ||
+ | copy tftp://tftp.server.addy/PowerConnect_5324-2014.ros image | ||
+ | Wait | ||
+ | copy tftp://tftp.server.addy/PowerConnect_5324_boot-10202.rfb boot | ||
+ | Wait | ||
+ | |||
+ | * It looks like when you upload a boot image it replaces the old one. On reboot the new boot image is loaded. You '''HAVE''' to select the new software before you reboot the switch or the switch may just keep looping. | ||
+ | |||
+ | * Quote from manual: Loading a new boot image from the TFTP server and programming it into the flash updates the boot image. The boot image is loaded when the device is powered on. A user has no control over the boot image copies. | ||
+ | |||
+ | So select the new system image before reboot: | ||
+ | |||
+ | show bootvar | ||
+ | boot system image-2 | ||
+ | |||
+ | Save the config: | ||
+ | copy running-config startup-config | ||
+ | |||
+ | |||
+ | Reboot the switch: | ||
+ | reload | ||
===Notes=== | ===Notes=== | ||
*http://www.latefortea.com/2009/09/minicom-cisco-and-xmodem/ | *http://www.latefortea.com/2009/09/minicom-cisco-and-xmodem/ | ||
+ | *http://stevejenkins.com/blog/2011/05/dell-powerconnect-5324-setup-tasks/ | ||
+ | *http://en.community.dell.com/support-forums/network-switches/f/866/t/19443085.aspx | ||
+ | |||
+ | |||
+ | =SNTP and Clock= | ||
+ | show clock detail | ||
+ | enable | ||
+ | clock source sntp | ||
+ | clock timezone -10 | ||
+ | |||
+ | enable | ||
+ | show sntp configuration | ||
+ | configure | ||
+ | sntp unicast client enable | ||
+ | interface vlan ## | ||
+ | sntp server 10.0.0.1 poll | ||
+ | sntp client poll timer 60 | ||
+ | sntp client enable | ||
+ | end | ||
+ | show sntp status | ||
+ | |||
+ | http://en.community.dell.com/support-forums/network-switches/f/866/p/18440016/18563647.aspx | ||
+ | |||
+ | =SNMP= | ||
+ | *http://en.community.dell.com/support-forums/network-switches/f/866/t/19513886.aspx | ||
+ | |||
+ | =LAG= | ||
+ | |||
+ | So when you put a port in lag, it ignores all other vlan settings. | ||
+ | |||
+ | VLANS AND LINK AGGREGATION GROUPS | ||
+ | |||
+ | On the PowerConnect M6220, when members are added to a link aggregation group (LAG), they are removed from all existing VLAN memberships. When members are removed from a LAG, they are added back to the VLANs that they were previously members of as per the configuration file. | ||
+ | NOTE: A port’s VLAN membership can still be configured when it is a member of a LAG; however, this configuration is only actually applied when the port leaves the LAG. Additionally, the port’s GVRP configuration is overridden by the LAG’s GVRP configuration. Upon leaving the LAG, the port will restore its GVRP configuration. The LAG interface can be a member of a VLAN complying with IEEE 802.1Q. The following discussion assumes an understanding of LAGs Please see the white paper “Link Aggregation Interoperability of the Dell PowerConnect™ M6220 with Cisco IOS or Cisco CatOS based Switches” for a in-depth discussion of M6220 LAG interoperability with Cisco switches. <ref>http://www.dell.com/downloads/global/products/pwcnt/en/pwcnt_VLAN_interoperability.pdf</ref> | ||
+ | |||
+ | show interfaces port-channel 1 | ||
+ | show interfaces status | ||
+ | *http://www.dell.com/support/article/us/en/19/HOW10364/EN | ||
+ | |||
+ | And one thing to remember about LAG groups, they don't really increase your bandwidth (4 - 1Gb links in a LAG group != a 4Gb link). "Any conversation between two actors over a LAG group will only achieve speeds of the fastest link in the LAG group." A LAG group does not multiplex the conversation over all members in the LAG to achieve a higher throughput. During a conversations between two actors only a single link is used. Where this is a benefit is when you have many actors in the conversation, there are more lines to communicate with. | ||
+ | |||
+ | =ToDo= | ||
+ | *Timeserver |
Latest revision as of 17:06, 18 January 2018
[Dell Powerconnect 5324 Userguide] [Dell Powerconnect 5324 Command Line Interface Guide]
This guy has a decent setup guide: http://stevejenkins.com/blog/2011/05/dell-powerconnect-5324-setup-tasks/
As far as passwords go it looks like the username/password thing by default is only for the web interface. When I set a line password for ssh I could use any username to login and it just asks for password.
Contents
Notes From Reading User Guide of Switch
- Page numbers and reference
- Passwords: 56
The SFP ports and ethernet ports 21-24 can not be used at the same time.
- The device has the following physical dimensions:
- Height — 44 mm (1.73 inch)
- Width — 440 mm (17.32 inch)
- Depth — 255 mm (10.03 inch)
Speed/link/activity is indicated on the left LED and the duplex mode is indicated on the right LED.
Diag lights 4 in a row.
The reset button, located on the front panel, manually resets the device.
minicom - Archlinux Install and minicom general use - Serialing in AKA Console Into Switch
To work with this switch you are going to need a NULL modem serial adapter or NULL modem cable to connect to the RS-232 Console Port. Once you have that The terminal settings are 9600 8N1 with no flow control. So 9600 baud, 8 data bits, 1 stop bit, and no parity. Flow Control NONE. VT100 Emulation.
pacman -Sv minicom lrzsz
General Use: minicom Settings for Dell 5324 Switch:
9600, 8, N, 1, Hardware flow control OFF
I had to set hardware flow control off to get the unit to accept input [1]. Software flow control worked. I also had to start with 9600, I think you can change the setting later.
One DB-9 connector for a serial terminal connection which is used for debugging, software download, etc. The default baud rate is 9600 bps. The baud rate can be configured from 2400 bps up to 38400 bps.
Reset Switch to Default Settings
enable delete startup-config reload
CLI
When using cli to save settings:
console# copy running-config startup-config
- http://www.dell.com/support/troubleshooting/us/en/555/Index
- http://en.community.dell.com/support-forums/network-switches/f/866/t/17879897.aspx
Set Console Password
enable config aaa authentication login default line aaa authentication enable default line line console login authentication default enable authentication default password yOurElitePassw0rd end
20 chars long seems to work and save your config:
copy running-config startup-config
Set Other Passwords
You can set other passwords for other lines (ways to connect) I think they are just enable passwords and such. You would still need users and passwords (prolly @ level 15) to use these services. The services are not automatically enabled. (I think except http)
Look at the user guide starting on page 56
Set Device IP Address
enable configure username admin password dell level 15 interface VLAN 1 ip address 192.168.1.123 /24 exit ip default-gateway 192.168.1.1 snmp-server community private rw exit
Test then save your config. You should be able to login (http,telnet) to the device.
Reset/Blank Password
It looks like a temp operation unless you save the settings. You have to console into the switch. Reset it. On startup of the switch you will be prompted to hit esc or enter:
Autoboot in 2 seconds - press RETURN or Esc. to abort and enter prom.
Afer you hit enter or esc you get 6 options. 3 clears the password. I bet you the password comes back on reset.
Enable SSH Server Management! Plus HTTPS?
I think you should still need to set a ssh line password. Though you may not have to. It looks like you do.
enable config crypto certificate 1 generate key-generate crypto key generate dsa crypto key generate rsa ip ssh server
If you want to change ssh port:
ip ssh port [port #]
If you want http server:
ip https server
If you want public key authentication for ssh:
ip ssh pubkey-auth
If you want to turn public key off after enableing?
no op ssh pubkey-auth exit
VLANS
Connect two trunk ports up that have the same vlans and the switches will pass data inbetween vlans. You can do the same with a LAG or what not too.
- http://en.community.dell.com/support-forums/network-switches/f/866/t/19335968.aspx
- Use web interface
- Page 254 of the UG though
- Page 40 and more in the CLI Guide
Table 7-65. VLAN Port Membership Table Port Control Definition
T The interface is a member of a VLAN. All packets forwarded by the interface are tagged. The packets contain VLAN information.
U The interface is a VLAN member. Packets forwarded by the interface are untagged.
F The interface is denied membership to a VLAN. Blank The interface is not a VLAN member. Packets associated with the interface are not forwarded.
Trunk VS General
Notes
- http://en.community.dell.com/support-forums/network-switches/f/866/p/17774016/17897002.aspx#17897002
- http://stevejenkins.com/blog/2011/05/dell-powerconnect-5324-setup-tasks/
Reset Configuration
Console into the switch. Reset it. On startup of the switch you will be prompted to hit esc or enter:
Autoboot in 2 seconds - press RETURN or Esc. to abort and enter prom.
press [2] within two seconds to erase flash file. Do Yes. The filename you want is:
config
Enter to continue and boot the device. Make sure to have the firmware file downloaded before you reset the switch that has your working internet connection on it.
Upgrading Switch Software
show version
- Software has a .ros extension
- Boot code has a .rfb extension
It looks like you do the software first and then the boot code. But you must do them both or your device will reboot over and over!
via console xmodem in linux
- For the above note: https://wiki.archlinux.org/index.php/Tftpd_server
How:
- Console In
enable reload
- Y to reboot the swtich
- Return or Esc within two seconds
- 1 to download software
Send file via xmodem. I use minicom. Along with minicom you need to have lrzsz installed. Some say to use screen with minicom because the transfer will take a while over serial. If you use screen and minicom you will need to change the escape key of one of them. Usually minicom under screen and keyboard (minicom -o)
Via TFTP
Do it this way.
- Setup a TFTP server https://wiki.archlinux.org/index.php/Tftpd_server
enable copy tftp://tftp.server.addy/PowerConnect_5324-2014.ros image
Wait
copy tftp://tftp.server.addy/PowerConnect_5324_boot-10202.rfb boot
Wait
- It looks like when you upload a boot image it replaces the old one. On reboot the new boot image is loaded. You HAVE to select the new software before you reboot the switch or the switch may just keep looping.
- Quote from manual: Loading a new boot image from the TFTP server and programming it into the flash updates the boot image. The boot image is loaded when the device is powered on. A user has no control over the boot image copies.
So select the new system image before reboot:
show bootvar boot system image-2
Save the config:
copy running-config startup-config
Reboot the switch:
reload
Notes
- http://www.latefortea.com/2009/09/minicom-cisco-and-xmodem/
- http://stevejenkins.com/blog/2011/05/dell-powerconnect-5324-setup-tasks/
- http://en.community.dell.com/support-forums/network-switches/f/866/t/19443085.aspx
SNTP and Clock
show clock detail enable clock source sntp clock timezone -10
enable show sntp configuration configure sntp unicast client enable interface vlan ## sntp server 10.0.0.1 poll sntp client poll timer 60 sntp client enable end show sntp status
http://en.community.dell.com/support-forums/network-switches/f/866/p/18440016/18563647.aspx
SNMP
LAG
So when you put a port in lag, it ignores all other vlan settings.
VLANS AND LINK AGGREGATION GROUPS
On the PowerConnect M6220, when members are added to a link aggregation group (LAG), they are removed from all existing VLAN memberships. When members are removed from a LAG, they are added back to the VLANs that they were previously members of as per the configuration file. NOTE: A port’s VLAN membership can still be configured when it is a member of a LAG; however, this configuration is only actually applied when the port leaves the LAG. Additionally, the port’s GVRP configuration is overridden by the LAG’s GVRP configuration. Upon leaving the LAG, the port will restore its GVRP configuration. The LAG interface can be a member of a VLAN complying with IEEE 802.1Q. The following discussion assumes an understanding of LAGs Please see the white paper “Link Aggregation Interoperability of the Dell PowerConnect™ M6220 with Cisco IOS or Cisco CatOS based Switches” for a in-depth discussion of M6220 LAG interoperability with Cisco switches. [2]
show interfaces port-channel 1 show interfaces status
And one thing to remember about LAG groups, they don't really increase your bandwidth (4 - 1Gb links in a LAG group != a 4Gb link). "Any conversation between two actors over a LAG group will only achieve speeds of the fastest link in the LAG group." A LAG group does not multiplex the conversation over all members in the LAG to achieve a higher throughput. During a conversations between two actors only a single link is used. Where this is a benefit is when you have many actors in the conversation, there are more lines to communicate with.
ToDo